תיאור
Leco
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
Rjdpfx Agoxxaxujbel
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
Rjdpfx Agoxxaxujbel
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נרשם מאז: 2012
שלח בקשה
טלפון & פקס
+49 2861 ... מודעות
ייתכן שגם מודעות אלה יעניינו אותך.
מודעה קטנה
Mögglingen
2,878 km
מכונת מדידה מתואמת
KEYENCEWM 3000
KEYENCEWM 3000
מודעה קטנה
Mainz
3,054 km
מיקרוסקופ אלקטרונים סורק (SEM)
ZeissXB 350
ZeissXB 350
מודעה קטנה
Borken
3,250 km
מכשיר אנליזה אלמנטרית יוקרתי
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
מודעה קטנה
Köln
3,188 km
שולחן עבודה עם אוויר נקי
HeraguardHPH 15
HeraguardHPH 15
מודעה קטנה
גרמניה
5,045 km
מערכת סינון - מערכת אוסמוזה
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
מודעה קטנה
Eindhoven
3,308 km
מיקרוסקופ דיגיטלי
KeyenceVHX-900/950F
KeyenceVHX-900/950F
מודעה קטנה
Borken
3,250 km
תא אקלים עם לחות, 34 ליטר
WeissWKL 34/40 -40...+150°C
WeissWKL 34/40 -40...+150°C
מודעה קטנה
Töltéstava
2,351 km
כרומטוגרפיית גז עם אוטוסמפלר, FID, מחשב ותוכנה.
Agilent6890N
Agilent6890N
מודעה קטנה
Mögglingen
2,878 km
מערכת מדידה
KEYENCEVR 3100
KEYENCEVR 3100
מודעה קטנה
Borken
3,250 km
תא בדיקת קורוזיה עם התזה מלוחה
VLMSAL 1000-FL PLC / V.715.362.520
VLMSAL 1000-FL PLC / V.715.362.520
המודעה שלך נמחקה בהצלחה
אירעה שגיאה