תא אקלים עם לחות, 34 ליטרWeiss
WKL 34/40 -40...+150°C
תא אקלים עם לחות, 34 ליטר
Weiss
WKL 34/40 -40...+150°C
מצב
משומש
מיקום
Borken 

התמונות מציגות
הצג מפה
נתונים על המכונה
מחיר ומיקום
- מיקום:
- Einsteinstraße 8a, 46325 Borken, Deutschland

התקשר
פרטי ההצעה
- מזהה מודעה:
- A20492700
- מספר התייחסות:
- 24870
- עדכון:
- עודכן לאחרונה בתאריך 10.11.2025
תיאור
Weiss
Model: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber volume: 34 litres
Feedthroughs included as standard:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for temperature testing:
Temperature range: -40 to +150 °C
Temperature deviations at steady state (according to IEC 60068-3-5):
Temporal fluctuation in centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4 K
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Max. heat compensation: 800 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Temperature and humidity fluctuations (at steady state, according to IEC 60068-3-5):
Temperature fluctuation (temporal, centre of usable space): ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3 K
Humidity fluctuation (temporal, centre of usable space): ± 3 to ± 5 % RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Protection (on site): 16A slow-blow
Heat output (air-cooled test chambers):
Gbedsxvpp Ropfx Adksw
Max. heat emission to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
“The table shown in the photos is not included in the sale.”
For your safety as a buyer, please note the following:
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications subject to change and error!)
If you have any further questions, we will gladly answer them by phone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
Model: WKL 34/40
Weiss Climate Chamber, Air-Cooled
-40°C to 150°C
Chamber volume: 34 litres
Feedthroughs included as standard:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Specifications for temperature testing:
Temperature range: -40 to +150 °C
Temperature deviations at steady state (according to IEC 60068-3-5):
Temporal fluctuation in centre of usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial deviation (temperature gradient): 2 to 4 K
Rate of temperature change (according to IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3.5 K/min
Max. heat compensation: 800 W
Specifications for climate testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % RH
Temperature and humidity fluctuations (at steady state, according to IEC 60068-3-5):
Temperature fluctuation (temporal, centre of usable space): ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K (temperature gradient): 1 to 3 K
Humidity fluctuation (temporal, centre of usable space): ± 3 to ± 5 % RH
Operating data:
Test chamber lighting: Halogen bulb 12V, 20W
Rated voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Rated power: 1.8 kW
Rated current: 8.0 A
Protection (on site): 16A slow-blow
Heat output (air-cooled test chambers):
Gbedsxvpp Ropfx Adksw
Max. heat emission to environment: 800 W
Refrigerant: R-404A
Weight: 110 kg
Important notice:
“The table shown in the photos is not included in the sale.”
For your safety as a buyer, please note the following:
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chamber undergoes a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data and specifications subject to change and error!)
If you have any further questions, we will gladly answer them by phone.