מערכת לטיהור מים למים אולטרה-טהורים, 400 ל'/שעה (RO + CEDI + UV)BVS Wassertechnik
Terion 400 l/h
מערכת לטיהור מים למים אולטרה-טהורים, 400 ל'/שעה (RO + CEDI + UV)
BVS Wassertechnik
Terion 400 l/h
מחיר קבוע בתוספת מע"מ
10,000 €
שנת ייצור
2022
מצב
משומש
(תפקוד מוגבל)
מיקום
Wien 

נתונים על המכונה
מחיר ומיקום
מחיר קבוע בתוספת מע"מ
10,000 €
- מיקום:
- Wien, Österreich

התקשר
פרטי ההצעה
- מזהה מודעה:
- A22348187
- עדכון:
- עודכן לאחרונה בתאריך 16.07.2026
תיאור
Complete, industrially manufactured water treatment system for ultra-pure, demineralized water, 400 l/h (< 3 µS/cm, depending on the raw water), delivered in December 2022. Multi-stage: raw water filter Berkofin KS25 HWS, compact demineralization ion exchanger BerkeSOFT midi 2-45, reverse osmosis Terion-S 500 with pressure pump/membrane modules, electrodeionization (CEDI), NaOH dosing for CO₂ removal, UVC sterilization Aquafides 1AF4+. 980-liter pure water storage tank with E+H Levelflex FMP51 and capacitive level sensors. Frequency inverter-controlled pressure boosting, 2 m³/h at 6 bar. High-quality industrial components (including KSB, Grundfos, Calpeda, WIKA, Bürkert, Balluff).
Technical data:
- Capacity 400 l/h, < 3 µS/cm; RO membrane set valid until 28.07.2025 (approx. 265 m³ treated)
Isdpfx Ahjzmap Nsneid
- UV lamp replaced on 01.10.2025 (approx. 5,350 operating hours); storage tank 980 l; pressure boosting 2 m³/h at 6 bar, frequency-controlled
- Note: CEDI unit currently defective/clogged, capacity currently ~20 l/h; repair offer dated 24.09.2025 is available. Extensive documentation and manuals are available.
More systems and equipment are continuously being offered for sale from a laboratory and pilot plant liquidation – inquiries are welcome.
Sold on behalf of the customer through the Köck auction house. Located in eastern Austria, exact address upon request. Collection/dismantling by the buyer.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
Technical data:
- Capacity 400 l/h, < 3 µS/cm; RO membrane set valid until 28.07.2025 (approx. 265 m³ treated)
Isdpfx Ahjzmap Nsneid
- UV lamp replaced on 01.10.2025 (approx. 5,350 operating hours); storage tank 980 l; pressure boosting 2 m³/h at 6 bar, frequency-controlled
- Note: CEDI unit currently defective/clogged, capacity currently ~20 l/h; repair offer dated 24.09.2025 is available. Extensive documentation and manuals are available.
More systems and equipment are continuously being offered for sale from a laboratory and pilot plant liquidation – inquiries are welcome.
Sold on behalf of the customer through the Köck auction house. Located in eastern Austria, exact address upon request. Collection/dismantling by the buyer.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נראה לאחרונה באינטרנט: בשבוע שעבר
נרשם מאז: 2026
10 מודעות אונליין
שלח בקשה
טלפון & פקס
+43 512 5... מודעות
המודעה שלך נמחקה בהצלחה
אירעה שגיאה




























