CTS CW-60/5.5 – Water-cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
Redpjx D Abpjfx Acuebt
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
Redpjx D Abpjfx Acuebt
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נרשם מאז: 2012
שלח בקשה
טלפון & פקס
+49 2861 ... מודעות
ייתכן שגם מודעות אלה יעניינו אותך.
מודעה קטנה
Borken
3,250 km
תא בדיקת אקלים בנפח 5,500 ליטר (5.5 מ"ק)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
מודעה קטנה
Deining
2,812 km
מבער דלק כפול
WEISHAUPT RGL 40/1-B // 2550kwMit Schaltschrank
WEISHAUPT RGL 40/1-B // 2550kwMit Schaltschrank
מודעה קטנה
Borken
3,250 km
תא בדיקת אקלים בנפח 5,500 ליטר (5.5 מ"ק)
CTSCW-60/5,5 -60°C bis +100°C
CTSCW-60/5,5 -60°C bis +100°C
מודעה קטנה
Borken
3,250 km
בודק מזג אוויר
AtlasXenotest Alpha LM
AtlasXenotest Alpha LM
מודעה קטנה
Euskirchen
3,181 km
מדחס בורג
FINIK-MAX 1510 VS (IE3)
FINIK-MAX 1510 VS (IE3)
מודעה קטנה
Geffen
3,323 km
שלדה עם תא נהג
ScaniaR500 NGS 6x2 Chassis cabine Stuur lift as
ScaniaR500 NGS 6x2 Chassis cabine Stuur lift as
המודעה שלך נמחקה בהצלחה
אירעה שגיאה