מנתח כימיBayer
Advia 1650
מנתח כימי
Bayer
Advia 1650
EXW מחיר קבוע בתוספת מע"מ
4,000 €
מצב
משומש
מיקום
Budapest 

התמונות מציגות
הצג מפה
נתונים על המכונה
מחיר ומיקום
EXW מחיר קבוע בתוספת מע"מ
4,000 €
- מיקום:
- Budapest, Hungary
התקשר
פרטי ההצעה
- מזהה מודעה:
- A14339923
- עדכון:
- עודכן לאחרונה בתאריך 26.11.2024
תיאור
The ADVIA 1650 has minimal requirements for sample volume (as low as 2 µL/test), reagent consumption (as low as 80 µL/test) and water consumption (25 L/hour) – thus maximizing management efficiency. A rapid, 3-second cycle and system throughput of up to 1650 tests/hour provide powerful high-speed performance, ensure workflow efficiency through peak workloads. Optional universal rack handler facilitates continuous sample feeding for further productivity gains.
Measurement point: 98 detection points/ 6 seconds in 10 minute reaction
Photometer: Concavity diffraction grating, rear spectroscopy system
Measurement wavelength: 14 fixed wavelengths (340, 410 ,451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm), 1 or 2 wavelenth calculation
Light source: 12V, 50W halogen lamp, cooled by forced water circulation
Assay method: Colorimetric assays – Endpoint assays (EPA), Reaction rate assays (RRA), 2-point rate assays (2PA), 3-item simultaneous measurement (parameter independent), Prozone checking (antigen excess check) Substrate depletion check with point forwarding option, Sample blank correction
Reassay mechanism: Automatic or manual (selectable)
Automatic correction: Blood serum blank, cell blank, measurement point change, sample volume change in reassay
Measurement method: Open discrete – Single line, simultaneous, multi item measurement
Throughput rate: Maximum 1650 tests/hour
Throughput rate biochemistry : Maximum 1200 tests/hour
Throughput rate electrolyte: Maximum 450 tests/hour
Sample throughput rate: Maximum 1200 samples/hour
Simultaneous measurement item: Maximum 103 items, normally 50 (main system) + 3 (ISE)
Measurement sample: Blood serum, plasma and urine (method dependent)
Containers: 5 mL, 7mL, 10 mL collection tubes (dead volume for collection tubes is 200 µL)
Cups: 1.8 mL JEOL sample cups (STT only), Hitachi 2 mL sample cups and Immuno 2 mL sample cups in 7 mL (16 x 75 mm) collection tubes (URH) or STT sample adapter (dead volume for sample cups is 50 µL)
Hfodpfx Aoqzx Ixsh Hon
No software with the unit. Please check out our other listings as well.
Measurement point: 98 detection points/ 6 seconds in 10 minute reaction
Photometer: Concavity diffraction grating, rear spectroscopy system
Measurement wavelength: 14 fixed wavelengths (340, 410 ,451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm), 1 or 2 wavelenth calculation
Light source: 12V, 50W halogen lamp, cooled by forced water circulation
Assay method: Colorimetric assays – Endpoint assays (EPA), Reaction rate assays (RRA), 2-point rate assays (2PA), 3-item simultaneous measurement (parameter independent), Prozone checking (antigen excess check) Substrate depletion check with point forwarding option, Sample blank correction
Reassay mechanism: Automatic or manual (selectable)
Automatic correction: Blood serum blank, cell blank, measurement point change, sample volume change in reassay
Measurement method: Open discrete – Single line, simultaneous, multi item measurement
Throughput rate: Maximum 1650 tests/hour
Throughput rate biochemistry : Maximum 1200 tests/hour
Throughput rate electrolyte: Maximum 450 tests/hour
Sample throughput rate: Maximum 1200 samples/hour
Simultaneous measurement item: Maximum 103 items, normally 50 (main system) + 3 (ISE)
Measurement sample: Blood serum, plasma and urine (method dependent)
Containers: 5 mL, 7mL, 10 mL collection tubes (dead volume for collection tubes is 200 µL)
Cups: 1.8 mL JEOL sample cups (STT only), Hitachi 2 mL sample cups and Immuno 2 mL sample cups in 7 mL (16 x 75 mm) collection tubes (URH) or STT sample adapter (dead volume for sample cups is 50 µL)
Hfodpfx Aoqzx Ixsh Hon
No software with the unit. Please check out our other listings as well.
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נרשם מאז: 2020
שלח בקשה
טלפון & פקס
+36 62 99... מודעות
המודעה שלך נמחקה בהצלחה
אירעה שגיאה