Mass SpectrometerAgilent
6210 G3258A, G1969A LC/MSD TOF
Mass Spectrometer
Agilent
6210 G3258A, G1969A LC/MSD TOF
EXW מחיר קבוע בתוספת מע"מ
25,500 €
מצב
משומש
(פועל באופן מלא)
מיקום
Győr 

נתונים בסיסיים
מחיר ומיקום
EXW מחיר קבוע בתוספת מע"מ
25,500 €
- מיקום:
- Győr, הונגריה

פרטי ההצעה
- מזהה מודעה:
- A16752511
- עדכון:
- עודכן לאחרונה בתאריך 27.12.2024
תיאור
Agilent 6210 G3258A, G1969A Time of Flight Liquid Chromatograph Mass Spectrometer LC/MSD TOF.
Bwedpfx Aljt Ui N Ujgow
The Agilent TOF is an orthogonal-axis time-of-flight mass spectrometer (oa-TOF). That is, the ions reaching the time-of-flight chamber are impelled in a direction perpendicular to their original path.
You can set up an Agilent time-of-flight mass spectrometer system (TOF) in several configurations:
-For normal flow LC/MS with a binary pump, quaternary pump, well-plate sampler (or autosampler) and ESI , APCI, APPI or MMI ion sources
-For microflow LC/MS with a capillary pump, micro well-plate sampler and ESI, APCI or MMI ion source
-For nanoflow LC/MS with a nanopump, micro well-plate sampler and nanospray source or dual nanospray source
-TOF system with an AP-MALDI source
Each system has advantages for drug discovery — high throughput sample screening with highly sensitive detection and accurate mass assignment.
Features:
ESI – Electrospray Ionization
APCI – Atmospheric Pressure Chemical Ionization
APPI – Atmospheric Pressure Photo Ionization
MALDI – Matrix-Assisted Laser Desorption Ionization
MMI – Multimode Ionization
Good working condition. Please check out our other listings as well.
Bwedpfx Aljt Ui N Ujgow
The Agilent TOF is an orthogonal-axis time-of-flight mass spectrometer (oa-TOF). That is, the ions reaching the time-of-flight chamber are impelled in a direction perpendicular to their original path.
You can set up an Agilent time-of-flight mass spectrometer system (TOF) in several configurations:
-For normal flow LC/MS with a binary pump, quaternary pump, well-plate sampler (or autosampler) and ESI , APCI, APPI or MMI ion sources
-For microflow LC/MS with a capillary pump, micro well-plate sampler and ESI, APCI or MMI ion source
-For nanoflow LC/MS with a nanopump, micro well-plate sampler and nanospray source or dual nanospray source
-TOF system with an AP-MALDI source
Each system has advantages for drug discovery — high throughput sample screening with highly sensitive detection and accurate mass assignment.
Features:
ESI – Electrospray Ionization
APCI – Atmospheric Pressure Chemical Ionization
APPI – Atmospheric Pressure Photo Ionization
MALDI – Matrix-Assisted Laser Desorption Ionization
MMI – Multimode Ionization
Good working condition. Please check out our other listings as well.