חימום ומפוחPCM Energy
חימום ומפוח
PCM Energy
שנת ייצור
2022
מצב
משומש
(פועל באופן מלא)
מיקום
Chemnitz 

נתונים על המכונה
מחיר ומיקום
- מיקום:
- Chemnitz, גרמניה

התקשר
פרטים טכניים
- כוח:
- 1,300 קילוואט (1,767.51 כ"ס)
- משקל כולל:
- 17,000 ק"ג
- טמפרטורה:
- 25 °C
פרטי ההצעה
- מזהה מודעה:
- A21276717
- עדכון:
- עודכן לאחרונה בתאריך 30.05.2026
תיאור
Description
A mobile PCM thermal storage unit
transports thermal energy (waste heat or process heat) using phase change materials (PCMs).
It stores heat through changes in its state of aggregation, achieving 2 to 4 times the capacity of conventional water tanks while maintaining compact dimensions. This system can be transported on a truck using a swap body system.
Storage capacity: 1.3 MWh of heat
Key operating principles & details
The principle (latent heat): Storage media such as paraffins or salt hydrates melt at specific temperatures, absorbing a large amount of heat in the process. When solidifying, this energy is released exactly at that temperature level.
Capacity & efficiency:
Since the energy (phase change) is stored without a noticeable temperature increase, the tanks have a significantly greater range. A modern mobile PCM storage unit typically holds storage volumes of several megawatt-hours (MWh).
Areas of application:
Perfect for supplying hospitals, schools, or swimming pools with district heating, or for residential complexes. The container can, for example, be fully charged at a biogas plant with excess heat and then transported to the point of use to release the heat.
Ideal for biogas plant operators or wood gas CHP plant operators, industry, etc., where process heat is available free of charge.
Technical data
Maximum
Storage temperature
75°C
Rcsdpoylmbqsfx Abyeb
Thermal storage capacity
gross 1300 kWh
Charging and discharging capacity max. 800 kW
Electronics on the storage unit: Data acquisition, monitoring, and transmission
Charging and discharging technology on the storage unit
Environmental compatibility: non-toxic, can be disposed of without harmful substances, recyclable
Connection: two supply and return lines, DN50, leak-proof, insulated, quick coupling
Grid connection: 400 kV
Logistics configurations: Standard container chassis, semi-trailer, swap body technology with twist locks,
trailer solution, adjustable thermal insulation hood
Dimensions: 6 x 2.55 m x 2.58 m (L/W/H) (~20 ft container)
Weight: 20 t
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
A mobile PCM thermal storage unit
transports thermal energy (waste heat or process heat) using phase change materials (PCMs).
It stores heat through changes in its state of aggregation, achieving 2 to 4 times the capacity of conventional water tanks while maintaining compact dimensions. This system can be transported on a truck using a swap body system.
Storage capacity: 1.3 MWh of heat
Key operating principles & details
The principle (latent heat): Storage media such as paraffins or salt hydrates melt at specific temperatures, absorbing a large amount of heat in the process. When solidifying, this energy is released exactly at that temperature level.
Capacity & efficiency:
Since the energy (phase change) is stored without a noticeable temperature increase, the tanks have a significantly greater range. A modern mobile PCM storage unit typically holds storage volumes of several megawatt-hours (MWh).
Areas of application:
Perfect for supplying hospitals, schools, or swimming pools with district heating, or for residential complexes. The container can, for example, be fully charged at a biogas plant with excess heat and then transported to the point of use to release the heat.
Ideal for biogas plant operators or wood gas CHP plant operators, industry, etc., where process heat is available free of charge.
Technical data
Maximum
Storage temperature
75°C
Rcsdpoylmbqsfx Abyeb
Thermal storage capacity
gross 1300 kWh
Charging and discharging capacity max. 800 kW
Electronics on the storage unit: Data acquisition, monitoring, and transmission
Charging and discharging technology on the storage unit
Environmental compatibility: non-toxic, can be disposed of without harmful substances, recyclable
Connection: two supply and return lines, DN50, leak-proof, insulated, quick coupling
Grid connection: 400 kV
Logistics configurations: Standard container chassis, semi-trailer, swap body technology with twist locks,
trailer solution, adjustable thermal insulation hood
Dimensions: 6 x 2.55 m x 2.58 m (L/W/H) (~20 ft container)
Weight: 20 t
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נרשם מאז: 2024
1 מודעה באינטרנט
שלח בקשה
טלפון & פקס
+49 176 3... מודעות
ייתכן שגם מודעות אלה יעניינו אותך.
מודעה קטנה
לטביה
3,049 km
בלוק תחנת חימום ותחנת כוח
SpannerBHKW45-8,0-V1.1
SpannerBHKW45-8,0-V1.1
מודעה קטנה
Frankreich
3,269 km
תחנת כוח חום וחשמל בבלוק
MTUCOGENERATIONENGINES AoE16V4000L62
MTUCOGENERATIONENGINES AoE16V4000L62
מודעה קטנה
גרמניה
3,006 km
תחנת חום וכוח משולבת
MAN/Daimler Benz/Krauter12 Zylinder/8 Zylinder
MAN/Daimler Benz/Krauter12 Zylinder/8 Zylinder
מודעה קטנה
Newton Aycliffe
3,890 km
130kW, 400V, 50Hz יחידות קוגנרציה לגז ביולוגי MAN / Marelli
MANUPB 12-L-W-E3262E302
MANUPB 12-L-W-E3262E302
מודעה קטנה
Brixen
2,642 km
תחנת חום וכוח משולבת
Spanner RE2 / Weissteiner Trockner
Spanner RE2 / Weissteiner Trockner
מודעה קטנה
גרמניה
2,920 km
גֵנֵרָטוֹר
Liebherr - AltronicG 924 TI
Liebherr - AltronicG 924 TI
מודעה קטנה
גרמניה
3,006 km
תחנת חום וכוח משולבת
KW Energiesmartblock 50
KW Energiesmartblock 50
מודעה קטנה
Krotoszyn
2,705 km
מייבש באפר, אורך 51 מטר
מודעה קטנה
Miastko
2,928 km
מערכת חילוץ נייחת
Nestro
Nestro
מודעה קטנה
La Muela
3,401 km
טורבינת גז טבעי
SolarTaurus 65
SolarTaurus 65
המודעה שלך נמחקה בהצלחה
אירעה שגיאה