Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Iijdjzd R Uwopfx Ac Ujc
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
המודעה תורגמה אוטומטית. ייתכנו שגיאות בתרגום.
Water-cooled temperature shock test chamber
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Iijdjzd R Uwopfx Ac Ujc
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.