The device is designed to cool tubes in CO2 laser plotters thanks to the use of a cooling unit. The CW5200 chiller keeps the water temperature at the right level. Thanks to such cooling, the tube has stable operating parameters.
The CO2 chiller ensures optimal working conditions of the tube, effectively protecting it against overheating and damage. The device is intended for people / companies where a laser plotter is an everyday work tool.
Technical Specifications:
Power supply - 230 [V]
Current consumption - 0.25 ~ 3.1 [A]
Compressor power - 0.59 [kW]
Cooling capacity - 1.7 kW / 5783 Btu / h / 1457Kcal / h
Coolant amount - 360 g
Tank capacity - 6 [L]
Connections (input / output) - 10 [mm]
Nlodpfx Afo Afnakshoh
Working height - 12 [m]
Flow - 13 [L / min]
Weight - 26 [kg]
Dimensions (L x W x H) - 58 x 29 x 47 [cm]
Security:
- Compressor overvoltage protection
- Alarm for incorrect water flow in the system
- Over temperature alarm
The price is a net price. Price does not include shipping costs.
PLEASE NOTE!!! This machine is a returned item; it is second-hand and has had its fluid refilled. NO WARRANTY!!
The CO2 chiller ensures optimal working conditions of the tube, effectively protecting it against overheating and damage. The device is intended for people / companies where a laser plotter is an everyday work tool.
Technical Specifications:
Power supply - 230 [V]
Current consumption - 0.25 ~ 3.1 [A]
Compressor power - 0.59 [kW]
Cooling capacity - 1.7 kW / 5783 Btu / h / 1457Kcal / h
Coolant amount - 360 g
Tank capacity - 6 [L]
Connections (input / output) - 10 [mm]
Nlodpfx Afo Afnakshoh
Working height - 12 [m]
Flow - 13 [L / min]
Weight - 26 [kg]
Dimensions (L x W x H) - 58 x 29 x 47 [cm]
Security:
- Compressor overvoltage protection
- Alarm for incorrect water flow in the system
- Over temperature alarm
The price is a net price. Price does not include shipping costs.
PLEASE NOTE!!! This machine is a returned item; it is second-hand and has had its fluid refilled. NO WARRANTY!!
ספק
הערה: הירשם בחינם או התחבר, כדי לקבל גישה לכל המידע.
נראה לאחרונה באינטרנט: היום
נרשם מאז: 2020
500 מודעות אונליין
שלח בקשה
טלפון & פקס
+48 25 63... מודעות
ייתכן שגם מודעות אלה יעניינו אותך.
מוצלח
ההודעה שלך נשלחה.
מודעה קטנה
Siedlce
2,563 km
מצנן S&A
CORMAKCW 5200TH
CORMAKCW 5200TH
המודעה שלך נמחקה בהצלחה
אירעה שגיאה