טורבינת קיטורČKD
Turbogenerator set 17,5MW
טורבינת קיטור
ČKD
Turbogenerator set 17,5MW
EXW VB בתוספת מע"מ
220,000 €
שנת ייצור
1958
מצב
משומש
מיקום
הרפובליקה הצ'כית 

התמונות מציגות
הצג מפה
נתונים על המכונה
מחיר ומיקום
EXW VB בתוספת מע"מ
220,000 €
- מיקום:
- 117, Vratimovská 689, 719 00 Slezská Ostrava, Czechia

התקשר
פרטים טכניים
- כוח:
- 17,500 קילוואט (23,793.35 כ"ס)
- תדירות כניסה:
- 50 הרץ
- טמפרטורה:
- 320 °C
- משקל כולל:
- 30,000 ק"ג
- מהירות סיבוב (מקסימלית):
- 3,000 סל"ד
- אורך כולל:
- 7,000 מ"מ
פרטי ההצעה
- מזהה מודעה:
- A19313691
- מספר התייחסות:
- TG4
- עדכון:
- עודכן לאחרונה בתאריך 06.06.2025
תיאור
ČKD, Turbogenerator set, condensate steam turbine 17,5MW
Manufacturer: ČKD
Power: 17 500 kW
Type:
RPM: 3000/ min
Steam pressure: 19 bar
Output steam pressure: 18 bar
Steam temperature: 320 ºC
The equipment is from year 1958 and has received all maintenance required for the maximum reliability, availability and capacity.
Size: 3500 x 3500x7000mm,
Weight:
Generator, gearbox, oil system and all related electro and InC equipment included.
We will send all technical data on request.
The machine has been regularly maintained and serviced since its commissioning. The period of GO and SO was carried out according to the actual condition. The repairs were carried out by the turbine manufacturer, the reconstruction (1969) and subsequent repairs were carried out by the 1st Brno Engineering Works. GO with replacement of blades was carried out in 1986 and SO in 2005 with standard scope of work. In the last period, routine maintenance and repairs were carried out by the local maintenance of the heating plant, when the following repairs were mainly carried out:
- control maintenance, oil. system, condensation
- maintenance of the heat exchanger station
Ibodpfx Aewqqa Nod Hsd
- maintenance of valves
Manufacturer: ČKD
Power: 17 500 kW
Type:
RPM: 3000/ min
Steam pressure: 19 bar
Output steam pressure: 18 bar
Steam temperature: 320 ºC
The equipment is from year 1958 and has received all maintenance required for the maximum reliability, availability and capacity.
Size: 3500 x 3500x7000mm,
Weight:
Generator, gearbox, oil system and all related electro and InC equipment included.
We will send all technical data on request.
The machine has been regularly maintained and serviced since its commissioning. The period of GO and SO was carried out according to the actual condition. The repairs were carried out by the turbine manufacturer, the reconstruction (1969) and subsequent repairs were carried out by the 1st Brno Engineering Works. GO with replacement of blades was carried out in 1986 and SO in 2005 with standard scope of work. In the last period, routine maintenance and repairs were carried out by the local maintenance of the heating plant, when the following repairs were mainly carried out:
- control maintenance, oil. system, condensation
- maintenance of the heat exchanger station
Ibodpfx Aewqqa Nod Hsd
- maintenance of valves